Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Ruskin - Dampers Louvers (816) 761-7476 Subject The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. Aluminum construction. Torque applied holding damper closed at 10 in. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowdamper that can be used as supply/return air plenum to connect to AHU unit below the ceiling assembly. With the variety of models, sizes, and paint finishes available, Ruskin Louvers can add unusual and appealing features to exterior and interior elevation. g. UL 555/555S 1. FILES (0) Share this page: Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. Ruskin’s smoke dampers are UL555S labeled with either electric or pneumatic actuators mounted internal (in air stream) or external (out of air stream). Louvers & Architectural. , with order). The webpage also includes diagrams, dimensions, and performance data of the dampers, as well as installation and maintenance instructions. Ruskin FDR25 is a true round fire damper designed for use in fire rated walls and floors and is the perfect choice when using round duct. Fire/smoke dampers must be installed so the leading edge of the closed blades are within the barrier it is intended to protect (unless specifically designed for out of wall or floor applications). Ruskin Control Dampers and Backdraft Dampers Get the air where you want it — when you want it! 3 CD60 Ultra Low Leakage Damper The CD60 damper is a “true” airfoil blade damper designed for medium to high velocity and. | Ruskin. Damper shall be in all respects equivalent to Ruskin BD6. g. Greaves Rd. Zone Control Systems. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. The EFL closes and locks the damper when temperatures exceed 165°F (74°C)Ruskin FDR25SS is a true round fire damper designed for use in fire rated walls and floors and is the perfect choice when using round duct. The TDPOSK is a highly accurate thermal dispersion airflow and temperature measuring probe. Dampers shall be Ruskin model FSDR25. lbs. The majority of designs are rated at 2 or 3 hours. Noise Control. The Quick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. The Ruskin optional firestopping installation is one of our latest installation instruction supplements we offer. V Groove & Single Blades. , which meets the International Energy Conservation Code (IECC) requirements. It features: Vertical blades. MODEL 914 SUGGESTED SPECIFICATION Suggested specification for Model 914 Ruskin Swartwout Fiber-glass Series round dampers (revision 6394). Damper shall be Ruskin model BTR82. Ruskin Construction has been intent on developing our marine capacity for two decades with the strategic acquisition of various marine construction companies in. II-U438-514/Replaces II-U438-408 ©Ruskin 2014 APPLICATION These installations are for all fire and combination fire and smoke damper installations in cavity shaft wall partitions and apply to the following wall design numbers as detailed in the UL fire Resistance directory: U415, U437, U438, U467, U469 and U497. The critical environment damper series is designed and manufactured with all the necessary features required to withstand the elements of coastal and corrosive applications. Details shown do NOT APPLY if your control damper has any of the following fea-tures: 1. (Consult for electronic version of this “Quick” spec as well as for complete 3- part CSI MasterFormat Specifications) Document Title Limited Warranty Document LINKS TO IMPORTANT DOCUMENTSFire and Smoke Dampers Ruskin actionair ES Series Operating And Maintenance Manual. Damper frames Dampers shall be constructed with premium vinyl ester resinsThe FD60 is a UL555 classified, 1-1/2 hour rated, multiblade fire damper. Ruskin Literature. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. All calculations are with external mounted actuators and accessories. Fusible Link which is included at no extra charge. Life Safety Products; Louver and Architectural; Louver Paint Finishes - Color Guide; Diffusers; Energy Recovery Ventilators; Commercial Control DampersRuskin - Dampers Louvers (816) 761-7476 Subject: The FSD60FA is a combination fire/smoke damper that allows through the grille access to the damper, actuator and heat actuated device. It features: Airfoil blades, which have greater strength, less static pressure, superior sealing ability, superior fire protection ability and produce less noise. Replacement Electronic Heat Sensors and Pneumatic Fuse Links for Combination Fire Smoke Dampers. C. These UL Classified dampers protect against heat, as well as flame, in ceilings with fire resistance ratings of 3 hours or less. Commercial Control Dampers; Sound Control; Industrial Control Dampers; Software. Learn about their history, products, news and experts on their website. Ruskin® was founded in the Ruskin Heights area of Kansas City in 1958. It is also: Flange mounted. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Ruskin (Thailand) Co. Mounting Angle Fasteners To sleeve #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476. . Triple V-groove Blade Airfoil Blade RUSKIN LIFE SAFETY DAMPERS Catalog. TION 1. added to the damper at fabrication. Ruskin FAST and PFMA are 20 guage steel mounting angles designed and approved for use specifically with Ruskin fire and fire/smoke dampers. and linkage shall be concealed in frame for low pressure drop and noise. angles together at corners of dampers. Dampers shall be in all respects equivalent to Ruskin model CBD6. static pressure. This folder features all of the latest literature that Ruskin has produced, available in. Ruskin Literature. The CD51 is structurally designed for velocities to 2000 fpm. Specifying and installing low-leakage dampers (Class 1 preferred, Class 2 at a minimum by code) helps ensure that the building HVAC system is operating at its most energy-efficient level. Damper shall be tested and licensed in accordance with AMCA 511 for Air Performance and Air Leakage. For best pressure drop and sound perfor-mance at higher velocities, consider an airfoil blade damper, such as Ruskin model CD60. Commercial Dampers. Greaves Rd • Kansas City, MO 64030 P: (816) 761-7476 (816) 765-8955 F: E: ruskin@ruskin. Actuators enable a damper to operate with controlled positioning throughout the stroke of the damper. Out of wall “OW” fire dampers are designed so that the leading edge of the damper frame can be up to 8" (203) out of the wall, partition or masonry floor. The SDRS25 is a UL555S Classified round smoke damper. or N. High Performance Ruskin Control Damper Model CD50 • Low Leak, extruded aluminum damper for higher velocity and pressure HVAC systems. 6) 304tested and classified Ceiling Dampers (also called Ceiling Fire Dampers or Radiation Dampers) to provide fire and heat protection where HVAC components penetrate the ceiling membrane. Ruskin Brands and Locations. Ruskin fire/smoke dampers can be rotated or turned over to accommodate the application. Find the conversion velocity (CV) by multiplying the selected size damper's area factor by the flow rate in CFM: CV = Area Factor x CFM. a. 8955DIBD20, 40, 60 fire dampers can be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. Nailor manufactures a unique and comprehensive line of products essential for a well designed HVAC system. 5 inches (89) Furnish and install, at locations shown on plans or as in accordance with. 3 sq. Ruskin May 2020 Page 1 Models CFD(R)2, CFD(R)3, CFD(R)3. Commercial Dampers. 0 psi. 5 Hour. CFDR7T - 2"x4" Truss Assemblies (Ref. static pressure. Ruskin’s low leak control dampers can save building owners up to $30 per damper 1 annually by providing tight sealing of outside air openings. Our plant in Thailand is well-equipped to manufacture next-generation products. Leakage information based on pressure differential of 1" w. II. of 8. Ruskin backdraft damper model CBDR82 is designed to open under flow and to prevent back-flow in industrial HVAC or process control systems. Ruskin manufactures an extensive line of UL rated and listed dampers to protect life and mitigate property loss during a life safety event. g. Ruskin Literature. g. Axles shall be square or hexagonal positively locked into the damper blade. COMMERCIAL CONTROL, MANUAL, AND. 3. pivot pins. 761. Ruskin CD30AF1/CD30AF2 con-trol dampers. The CDO25 is an oval control damper that features: Volume control. Material thickness shall be equivalent to Ruskin model CDR25 or CDO25 standard construction. Damper widths from 12" to 60" (305 to 1524) wide shall not leak any greater than 8 cfm sq. Each has added features that enable them to meet all high temperature, high pressure. Ruskin fire/smoke dampers. g. The damper is rated for maximum velocity of 2,000 fpm (10. While providing fresh air intake and exhaust, Ruskin Louvers can also provide architectural style to building design. The CFDR5 is a Round, UL555C Classified Ceiling Fire Damper. Spec AIRFLOW-IQ-0121 STATD SPTS R ST T TT T R T. Title: CDRS82- Spec Author: Ruskin Created Date:The CFDR7T is UL555C Classified Ceiling Fire Damper for wood construction. 5 21w ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Figure 5. It locks together without bolts, screws, or rivets that could shake loose. Equipped with linkage out of the airstream. This damper is fitted with a counterweight assembly that can be field adjusted and calibrated to meet the specific airflow requirements of your unique system. Consult Ruskin or your Ruskin repre-sentative when a damper is to be applied in conditions exceeding recommended maximums. We offer a wide variety of products to mee. With the variety of models, sizes, and paint finishes available, Ruskin Louvers can add unusual and appealing features to exterior and interior elevation. Damper Dia. The maximum opening. 350° Horizontal FSD36LP 36"x 14" 4"w. max. When ordered, as an option, the DTS will beThe DFD60 is a UL555 classified, 1 1/2 hour rated, multiblade fire damper. Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476. Pottorff is a leading manufacturer of AMCA- and UL-certified HVAC louvers and dampers for commercial applications. Windstops all around. Share this page: Guillotine "fire damper" fabricated from a fire resistant panel used in the construction of 3 hour UL tested and labeled sliding fire doors. Masonry/Wall or Floor: #10 self-tapping concrete screws. Counter Balanced Backdraft Damper. (1 kPa) static pressure and shall be tested and rated to close with airflow in either direction. • UL555S requires that all combination fire smoke dampers have factory mounted actuators in order to bear the UL label. com . Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowRuskin continues to provide the industry with the most UL approved field installation solutions for fire and fire/smoke dampers. The FSDR60 is a "true round" Class 1 leakage rated combination fire and smoke damper designed for use in metal, wood or concrete fire and smoke rated partitions and concrete floors. g. (2) 1/4-20 Nuts 2. Ruskin recommends appropriate bracing to support the damper horizontally at least once for every 8 'of. Use "Mount With Arrow Up" label as a guide for proper damper orientation. Ruskin model CD60 offers HVAC design engineers an ultra-low leak high performance damper which provides: • Energy savings for building owners • Low noise generation and lowest pressure drop • Low maintenance Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Insulating Control Dampers. 25" w. back pressure depending on damper size. The damper and sleeve assembly can be installed completely from one side of the wall and does not require mounting angles on the backside. Mounting Angle FastenersCurtain Type Static Fire Dampers 3 Hour Ul555 Rated For Use In Static Systems Ruskin Model IBD23 is a 3 hour UL classified static (fans off) curtain style fire damper for use in HVAC systems that shut down during a fire event. It features: A static pressure control option, which enables field adjustment to maintain static pressures ranging up to . Do not weld or fasten angles together at cor-ners of dampers. Leakage ratings are based on AmCA Standard 500 using Test Setup Apparatus Figure 5. From our humble beginnings with a handful of employees building fire dampers, Ruskin has grown into the largest and most innovative manufacturer of air control solutions with 29 production and office locations worldwide. w. The CD50 was the first AMCA-licensed low leakage damper and bears the AMCA Air Leakage Seal. 5hr Static Fire Dampers » 3hr Static. If the actuator must be mounted on top or bottom, select the FSD60V. They also offer a new coupler option that joins two damper sections without a jackshaft allowing an actuator to be mounted on side of frame to provide a narrow profile when space is limited. Ruskin provides perfect control Fire Smoke Dampers. Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. The damper shall be rated for dynamic closure at 2000 fpm (10. (2) ‘S. Electric and pneumatic actuators are available with numerous accessories and mounting. When used in fan discharge applications, damper should bethe damper frame. When used in fan discharge applications, damper should be located at least one-half the fan diameter away from the fan. See “Smoke Damper Multiple Section Detail” spec sheet for details. Most F/Cs andSMOKE & COMBINATION FIRE SMOKE DAMPER ACTUATORS. g. Testing has proved that the CD40x2 insulated more efficiently than conventionally insulated blades. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. Dampers above 40" (1016) – 10 gage with retainer ring. Ruskin Literature. Unequal section sizes. Ruskin fire/smoke dampers can be rotated or turned over to accommodate the application. • Airfoil blade design for low pressure drop and reduced noise generation. Enter the Pressure Drop Chart at the determined area factorRuskin April 2021 Page 3 DAMPER SLEEVE DIMENSIONAL DATA The drawings show the position of the damper mounted in the factory sleeve. Ruskin provides perfect control Fire Smoke Dampers. And with Ruskin Expressthese labor saving fire dampers can be shipped tomorrow! FAST Angle One Side Dampers are available in sizes and styles that meet your specific job requirements. ft. g. Following system stabilization, normal counter-balance operation will continue. The results show that Ruskin’s CBS8BL dramatically reduces the blast impulse thus protec Ruskin blast damper charts below highlight results of independent third party lab testing of model CBS8BL to peak reflective pre B Impl ( ows ra m Ope nDu ct) Blast Impulse (Downstream Damper)of damper with minimum of 20 in. Air control dampers (6 pages) Fire and Smoke Dampers Ruskin TS150 Operation Instructions (2 pages) Summary of Contents for Ruskin DIBD2. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 ® Nominal Diameter, Inches Total CFM. a. The DTS gives maintenance personnel the ability to “cycle test” the fire/smoke damper by pushing and holding the button until the damper has cycled. The Quick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. It features: 750 degree F standard temperature rating! A variety of applications in air and material volume control systems. Control dampers shall be produced in an ISO9001 certified factory. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. Butterfly blade. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowon dampers with v-groove blades, we recommend sizing dampers for 1,500 fpm. Greaves Rd. Fire dampers are UL555 tested and labeled devices installed in ducts and air transfer openings or air distribution systems, designed to close upon the detection of heat. 165°F or 212°F (74°C or 100°C) (specify temperature) fusible volume adjustment options are available. Providing accurate control or isolation of. Each fire damper shall be labeled for use in dynamic systems. It is Leakage Class I classified and features: UL555S Class I. TION 1. g. 1/4” cfm at 4” w. It can be equipped with the industry's shortest sleeve and is ideally suited for shaft wall applications. Grandview, MO 64030 View our location on Google Maps Phone: 816. The damper frames are made of galvanized steel in a channel frame construction, offering an equivalent 13-gauge metal strength. com W: Genset dampers are designed to provide maximum combustion air and pressure relief quickly for emergency generator start up to avoid damage of equipment or surrounding space. Noise Control. lbs. • Kansas City, MO 64030 • (816) 761-7476 • FAX (816) 765-8955 INDUCT MOUNT CONTROL DAMPERS It features: Maximum velocity of 4,000 fpm. Aluminum Airfoil Blades. g. Consult Ruskin or your Ruskin repre-sentative when damper is to be applied in conditions exceeding recommended maximums. The CDR82 Round Control Damper features: Accurate airflow control within round ductwork systems in medium pressure industrial HVAC systems Desired performance easily attained in pressure differentials of 6"w. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. Damper shall be equivalent to Ruskin model ARD25. Quick Select. DaMpER aSSEMBliES The MD35 is intended to be self supporting only in its largest single section size. g. g. 3 (damper installed with duct upstream and downstream). Built from strong materials and designed on state-of-the-art. F. The CDRS15 is a true round commercial control damper that installs easily in round spiral ductwork. These products are well suited for both retrofit applications as well as new construction. Constructed with durable galvanized steel. Static only damper labels are not permissible. II-U438-514/Replaces II-U438-408 ©Ruskin 2014 APPLICATION These installations are for all fire and combination fire and smoke damper installations in cavity shaft wall partitions and apply to the following wall design numbers as detailed in the UL fire Resistance directory: U415, U437, U438, U467, U469 and U497. Do not weld or fasten angles together at corners of dampers. Innovative thermally efficient dampers are fabricated utilizing high yield 6063T6 frame and blade extrusions. 5 illustrates a plenum mounted damper. 1. • Operation Test The damper/actuator assembly is exposed to heated (250ºF or 350ºF) airflow (minimum 2,400 fpm and 4. The standard finishes described herein represent those finishes usually selected, specified, or required for most. Static pressure and CFM are corrected to. The CD60GS is designed to provide maximum combustion air and pressure relief quickly for emergency generator start up to avoid damage of equipment orsurrounding space. FACE and BYPASS MIXING DAMPERS Dampers larger than maximum single section are an assembly of equal size single section dampers (maximum section size 48"w x 72"h (1219 x 1829) and may be coupled for operation in a variety of ways. FILES (0) Share this page: Trusted for decades, Ruskin V-Groove blade dampers were designed to extend a lower cost solution for standard duty (medium or low pressure) applications. g. A 1" (25) diameter jackshaft is normally used for. The ARD25 is. As a Corridor Damper it is designed to be used in openings in the ceilings ofRuskin anuary 2021 Page 2 1. Ruskin Literature. Shop custom order Ruskin Dampers and Airflow products for your HVAC needs. 3. To determine the pressure drop: 1. Frame shall be 16 ga. The ratings shown are based on tests and procedures performed in accordance with AMCA Publica-tion 511 and comply with the requirements of the AMCA Certified Ratings Program. (2 kPa). Industrial FAQs. Determine area factor for damper by entering the Area Factor Table through duct width and height. Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476. Horizontal Installation – 6"w x 6"h (152 x 152). The FSD60FA da mper may be installed. The critical environment damper series is designed and manufactured with all the necessary features required to withstand the elements of coastal and corrosive applications. g. This catalog offers Damper customers an easy to use buying guide for miscellaneous Ruskin Damper parts. Ruskin FAST and PFMA are 20 gauge steel mounting angles designed and approved for use specifically with Ruskin fire and fire/smoke dampers. 3. 2. the damper/sleeve. a. Steel construction with aluminum paint finish. ©Ruskin February2016 Model FSD60GA and FSD36GA series meet the requirements for combination fire and. Dampers shall be designed for maximum 1500 fpm spot velocities and up to 4" w. Axles that positively lock to blades without screws or welds. Dampers shall be in all respects equivalent to Ruskin model IL35. Some of the approved ceiling designs are L501,. — Ruskin ® announces three new emergency generator inlet dampers (GenSet) designed to quickly open to relieve combustion air. ) SUGGESTED SPECIFICATION STATIC PRESSURE (Inches Water Gage) AIR FLOW IN C. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. Multi-section dampers typically use jackshafts to link sections together. Horizontal dampers installed in walls and floors shall have extended dynamic closure and operational ratings of 4000 fpm (20. Ruskin Company certifies that the SD50 shown hereon is licensed to bear the AMCA Seal. The FSD60 can be installed in horizontal or vertical applications and has low leakage and pressure drop ratings. Ruskin triple V blade fire/smoke dampers do meet the 3000 fpm, 4" w. The DIBD20, 40, 60 carry a 1 1/2 hour UL fire damper label and are classified as a dynamic damper for use in HVAC systems that remain in operation during a fire. Built from. 8955 DIBD20, 40, 60 fire dampers can be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. In addition, the DC models have. Note: Multiple section dampers are not intended to. UL approval for dual directional airflow. 3 (damper installed with duct upstream and downstream). Ruskin July 2020 Page1 CD60DC (DATA CENTER) High-performance Galvanized Steel Airfoil Blade Damper AMCA Class IA Leakage Rated The CD60DC is designed for HVAC systems serving data center facilities where high performance and reliability is expected. 5. INSTALLATION For proper operation, damper must be installed square and free from racking. From dampers and louvers, to air measuring systems and ERVs, Ruskin ® is recognized for consistent innovation, engineering excellence and precision manufacturing. The CD40x2 has an 8" frame and aluminum construction. The damper/actuator assembly is exposed to elevated temperatures for 30 minutes and then immediately cycled three times. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. The switch package shall include two position indicator switches linked directly to the damper blade to provide full open and full closed damper blade position. Fasteners and Multiple Section Assembly When joining multiple damper assemblies or fastening the damperThe S2SS Backdraft damper has a 2" frame. Multiple section damper assemblies may require brac - ing to support the weight of the assembly and to hold against sys - tem pressure. Ruskin Fire, Smoke, and combination fire/smoke dampers meet the strict requirements established by the International Fire Code (IFC) and the International Building Code (IBC). Access Doors. Multiple section dampers are available in unlimited sizes. 5, CFD4 and CFD(R)5 are UL labeled ceiling radiation dampers. Access Doors. 350° Vertical or Horizontal SIze StAtIC PReSSURe teMPeRAtURe INStALLAtIoN ACtUAtoR ReqUIReMeNtS * UL555S requires that all. Ruskin Headquarters are located in the Southeastern portion of the Greater Kansas City Metropolitan area Mailing Address: Ruskin Company 3900 Dr. Figure 5. Linkage shall be concealed, out of airstream, within the damper frame to reduce pressure drop and noise. It: Is standard on all fire/smoke dampers ordered with pneumatic actuators. per sq. Ruskin Fire/Smoke Dampers. Learn how to select the best damper for your system and achieve optimal air. per sq. Readily connects to round spiral or flexible ductwork. Ruskin model SD50 offers HVAC design engineers an ultra-low leak high performance Leakage Class I smoke damper which provides: • Barrier to stop smoke • Lowest pressure drop for energy savings • Optional fail open operation for smoke exhaust applications • Highest dynamic closure rating of 4,000fpm & 8” static pressure. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (3) steel rivets or 1/2" (13) long welds. Consult Ruskin or your Ruskin representative when damper is to be. Ruskin Model ZCDR25 can be installed into existing round ductwork. 3. Zone Control Systems. It features: 1-1/2 hour rating. Available with factory furnished sleeves. 25" w. Pressure limitations shown above allow maximum blade deflection of 1/180 of span on 60" (1524) damper widths. 1. a. Each fire damper shall be labeled for use in dynamic systems. 125" (3. TDP05K Placement Tool. Galvanized Steel V-Groove Blades. 5 illustrates a plenum mounted damper. , Ltd. 8955From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. Combination Fire/Smoke dampers are low leak damper and actuator assemblies that have passed the UL555 and UL555S test requirements. The DIBD20, 40, 60 carry a 1 1/2 hour UL fire damper label and are classified as a dynamic damper for use in HVAC systems that remain in operation during a fire. Get free shipping on orders over $999!%PDF-1. INSTALLATION CD355 SERIES DAMPER IS NOT RECOMMENDED FOR INSTAL- Ruskin August 2020 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Multi-section Dampers Dampers over the maximum single section size will require multiple damper sections, typically built in equal sizes. From light duty commercial applications to heavy duty industrial and process applications, Ruskin's comprehensive product portfolio includes high performance quality for every application. angles together at corners of dampers. Conservative ratings are pre - sented intentionally in an effort to avoid misapplication. It features: Maximum velocity of 4,000 fpm. The bubble tight isolation damper shall be manufactured in an ISO9001 certified factory. DAMPER SIZESRuskin CD60 Commercial Control Dampers Type for a low price! Get free shipping on orders over $999!. damper section width as indicated. w/ damper - - ELF6375DXD Horizontal drainable blade Wind-borne debris regions (non-essential buildings), HVHZ, areas with rain management system ±148 6” N/A TDI Water, Air 540 & 550 w/ damper ELC6375DXD Horizontal drainable combination louver/ damper Hurricane-prone regions, HVHZ, areas with rain management system, applications. Dampers shall be Ruskin CD60 model. Actuators are designed to operate reliably in smoke control systems requiring Underwriter’s Laboratories, Inc. 765. DIMENSIONAL DETAILS SUGGESTED SPECIFICATION 3900 Dr Greaves Rd. Unless specifically ordered otherwise, when looking at the concealed linkage side of the damper and the bottom blade turnsA. Dampers shall be in all respects equivalent to Ruskin model CBD2. They are easy to install, easy to use, and are customizable to the needs of any building automation system. Must be installed in the factory. Multi-section dampers typically use jackshafts to link sections together. The SD60M is a UL555S Classified Leakage Class I modulating smoke damper. Deflections in other damper widths (less than 48" [1219]) at Smoke dampers are UL555S tested and labeled, low leak damper and actuator assemblies constructed to restrict the spread of smoke in HVAC systems that are designed to be automatically shut down in the event of a fire, or opened to control the movement of smoke within a building when the HVAC system is part of an engineered smoke control system. GRANDVIEW, Mo. Access doors provide an easy means of reaching damper components inside the ductwork. Each has added features that enable them to meet all high temperature, high pressure. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. Dampers shall be Ruskin Swartwout Series Mod el 912 FRP control dampers or equal. The operable blades are opened and closed manually, or with the use of an actuator. The 316SS construction offers excellent corrosion resistance. static pressure. From our humble beginnings with a handful of employees building fire dampers, Ruskin has grown into the largest and most innovative manufacturer of air control solutions with 29 production and office locations worldwide. Determine the airflow in CFM. SUGGESTED SPECIFICATION 3900 Doctor Greaves Road Grandview, MO 64030 Website: AUTHORITY IN AIR CONTROL. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Masonry Wall or Floor: #10 s elf-tapping concrete screws Wood/Steel Stud Wall: #10 screws. The CD51 can be utilized in systems calling for less than 10 cfm/sq. Actuators & Damper Accessories Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. Ruskin’s adjustable louvers and louver/damper combinations allow our customers to enjoy the benefit of architectural styling with air control and shut off. Sun Control Sunshades. While providing fresh air intake and exhaust, Ruskin Louvers can also provide architectural style to building design. Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. When joining multiple damper assemblies or fastening the damper to the sleeve, dampers shall be fastened with 1/4-20 (M6) bolts, number 10 (M5) screws, or 1/2" (13) long welds stag-gered intermittently on both sides. The damper is rated for Ruskin CD50DC is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. 5 hr. It features: Airfoil blades, which have greater strength, produce less sound, greater sealing ability, and static pressure loss. It features: Extruded aluminum construction. The FDR25 is rated for maximum velocity of 2,000 fpm and 4” w. While is it true that triple V blade dampers and modified single skin type have been qual-ified to 3000 - 4000 fpm or more at 4" w. Multiple velocity and temperature points on one or more probes installed in the duct or plenum are averaged to arrive at air measurements. Ruskin fire dampers may be installed using Ruskin PFMA. Damper Width “A” Dimension in inches (mm) » Tunnel Fire Dampers DISCLAIMER: The Ruskin® brand’s (hereinafter “Ruskin”) content, functionality and product information provided in this data file, including Ruskin design and dimensions (collectively referred to herein as “Ruskin’s Information”) are offered solely to you as a convenience and are for your information only. Keywords: Ruskin, Commercial, backdraft, damper S3G, Data, Submittal, galvanized, steel Created Date: 1/5/2017 12:58:19 PMRUSKIN finishes enhance product appearance to blend with other colors selected. Shop custom order Ruskin Dampers and Airflow products for your HVAC needs. • Fire smoke dampers larger than single section may require multiple actuators. Commercial Control Damper CD60. Share this page: From light operations to heavy-duty industrial applications and from backdraft control to indoor air quality control, Ruskin provides the perfect control. Find the conversion velocity (CV) by multiplying the selected size damper's area factor by the flow rate in CFM: CV = Area Factor x CFM 3. The Model IBDT is a thinline fire damper that can be installed vertically in walls and partitions or horizontally in masonry floors with fire resistance ratings of less than 3 hours. Maximum 8" static pressure UL approval for dual directional airflow Failsafe design, which enables the damper to automatically assume the desired. Offset single blade design lets Ruskin engineers calibrate the damper operation to exact customer specification.